| Stainless Steel Wire Braid PV Cable 1000/2000V | ||
| Voltage: | 1000/2000V | |
| Structure: | Conductor | Tinned copper, Class K |
| Inner Insulation | XLPO | |
| Outer Insulation | XLPO | |
| Braid | Stainless steel wire braid, 85% | |
| Insulation Colors | Black | |
| Outer Sheath Colors | Black Red | |
Cables applied for use in Photovoltaic Systems, in particular for installation of connecting solar panels at Direct Current section.
1000/2000V
-40~90°C
8xD (D is diameter of cable)
6xD (D is diameter of cable)
UL4703
UL44
Tinned copper, Class K
XLPO
XLPO
Stainless steel wire braid, 85%
Black
Black Red, other colours available on request
| Size | Conductor | Nominal thickness of Insulation | Dia. of steel wire | Approx. Overall Diameter | Approx. Weight |
| AWG | mm | mm | mm | mm | kg/km |
| 10 | 105/0.25 | 1.14/0.76 | 0.12 | 7.6 | 110 |
| 8 | 168/0.25 | 1.39/0.76 | 0.12 | 9.1 | 160 |
| Size | Max. Conductor DC resistance at 20℃ | Min. Insulation resistance at 15℃ | Ampacities of Single-Insulated Conductors in Free Air where the ambient temperature is 30°C | ||
| AWG | Ω/km | MΩ·km | 60℃ (A) | 75℃ (A) | 90℃ (A) |
| 10 | 3.66 | 950 | 40 | 50 | 55 |
| 8 | 2.18 | 1040 | 60 | 70 | 80 |
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.
Generally, we can deliver regular machines to customers immediately within 7-30 days.
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.
Sampling test items: cable conductor DC resistance; finished cable withstand voltage test;conductor single wire diameter and deviation;insulation average thickness, thinnest point;The sheathed average thickness and thinnest point
Sampling test items: cable conductor DC resistance; finished cable withstand voltage test;conductor single wire diameter and deviation;insulation average thickness, thinnest point;the sheathed average thickness and thinnest poin;change rate of tensile strength and elongation of insulation and sheath before and after aging;insulated wire core withstand voltage test;hot extension test;ozone resistance test;finished cable flexure test, etc.
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.
Generally, we can deliver regular machines to customers immediately within 7-30 days.
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.