| 1000/2000V Solar Photovoltaic Wire with Nylon Jacket | ||
| Voltage: | 1000/2000V | |
| Structure: | Conductor | Copper conductor, Class B |
| Insulation | XLPO/XLPO composite insulation | |
| Jacket | Nylon (Anti-rodent) | |
| Inner Insulation Colors | Black | |
| Outer Insulation Colors | Black Red | |
| Nylon Colors | Natural | |
Cables applied for use in Photovoltaic Systems, in particular for installation of connecting solar panels at Direct Current section.
1000/2000V
90°C
12xD (D is diameter of cable)
10xD (D is diameter of cable)
UL4703
Copper conductor, Class B
XLPO/XLPO composite insulation
Nylon (Anti-rodent)
Black
Black Red, other colours available on request
Natural
| Size | Construction of conductor | Inner Insulation Thickness | Outer Insulation Thickness | Nylon Thickness | Approximate O.D. | Approximate Weight |
| AWG | mm | mm | mm | mm | mm | kg/km |
| 10 | 7/0.98 | 1.14 | 0.76 | 0.2 | 7.3 | 90 |
| 8 | 7/1.23 | 1.39 | 0.76 | 0.2 | 8.6 | 135 |
| Size | Minimum bend radius | Conductor resistance at temperature 20℃ | Conductor resistance at temperature 90℃ | Maximum pull | Allowable ampacities in air* | Allowable ampacities of multiple cables** |
| AWG | mm | Ω/km | Ω/km | N | A | A |
| 10 | 88 | 3.41 | 4.35 | 362 | 55 | 40 |
| 8 | 103 | 2.14 | 2.73 | 577 | 80 | 55 |
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.
Generally, we can deliver regular machines to customers immediately within 7-30 days.
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.
Sampling test items: cable conductor DC resistance; finished cable withstand voltage test;conductor single wire diameter and deviation;insulation average thickness, thinnest point;The sheathed average thickness and thinnest point
Sampling test items: cable conductor DC resistance; finished cable withstand voltage test;conductor single wire diameter and deviation;insulation average thickness, thinnest point;the sheathed average thickness and thinnest poin;change rate of tensile strength and elongation of insulation and sheath before and after aging;insulated wire core withstand voltage test;hot extension test;ozone resistance test;finished cable flexure test, etc.
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.
Generally, we can deliver regular machines to customers immediately within 7-30 days.
Our team is available 24/7 to respond to customer inquiries and issues. Most issues can be resolved within 8 hours.